Description
Product Features
- Memory capacity is 8100 lines of data per channel. (It is possible to store the data for about 506 days with log interval of 90 minutes.)
- The method of storing data can be selectable among four logging options. (Once, Repeatability, Ends at, By page)
- The date and time to start logging automatically can be specified by setting the preset start.
- The measurement data can be transmitted in realtime to a personal computer.
- USB transmission is adopted.
- The upper and lower thresholds for warning can be set. When the temperature or humidity threshold is triggered, the alarm mark (Hi or Lo) will light.
- Display Functions: TIME (display time), INT (log interval) REC (during logging). RES (during preset standby), OUT (during real-time tranmission), LCD bars (used memory) CALL (call for the current measurement data during logging) Current temperature, Current humidity, Current date and time, low battery mark, Temp. upper limit (Hi), Temp. lower limit (Lo), Humi. upper limit (Hi), Humi. lower limit (Lo), Temp. alarm ON (Alarm), Humi. alarm ON (Alarm), logging option, setting value of upper and lower limits. errer message, ID number
- Probes are interchangeably used with main units.
- The storage memory can be varified with the memory indicator.
- The log interval can be selected from 14 options: 1 sec, 2 sec, 5 sec, 10 sec, 15 sec, 30 sec, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, 60 min. and 90 min.
- When the power is turned off, data stored in the EEPROM memory is retained.
- The datalogger ID can be set. This is useful to identify multiple dataloggers.
- By using data analysis software attached, acquired data can be evaluated easily and quickly, and also evaluated by using commercial spreadsheet software supporting the “CSV” extension such as Lotus 1-2-3 and Microsoft Excel.
- Software for data analysis and realtime transmission (CD-Rom)
- USB cable (1.5m)
- USB port cap (factory set)
- Hand strap
- 2 alkaline batteries
- Instruction manual
- (Probe is not attached)
Product Specs in SI
Model | HSK-L200TH II |
---|---|
Display Range (Temp.) | 5 to 149 °F (depending on a probe connected) |
Display Range (Humi.) | 10 ~ 99.9 % RH |
Resolution (Temp.) | 0.1 °F at 14.18 to 149 °F 1 °F at 14 °F or less |
Resolution (Humi.) | 0.1 % RH at 15.0 to 99.9 % RH 1 % RH at less than 15.0 % |
Accuracy (Temp.) | +/- (0.1 °F + 1 digit) |
Accuracy (Humi.) | +/- (0.1 % RH + 1 digit) |
Probes Connected | SK-LTH II series probes |
Sampling (Display) | About 1 sec. |
Communication | USB |
Operation Ambient | 14 to 140 °F, no condensing |
Storage Ambient | 32 to 122 °F |
Power Requirement | AAA size Alkaline battery x 2 |
Battery Life | More than 500 hours |
Dimensions | 3.94W x 2.87H x 0.87D IN |
Weight | About 0.27 LB (exclusive of batteries) |
Material | ABC resin |
Product Specs in Metric
Model | HSK-L200TH II |
---|---|
Display Range (Temp.) | -15 to 65.0 °C (depending on a probe connected) |
Display Range (Humi.) | 10 ~ 99.9 % RH |
Resolution (Temp.) | 0.1 °C at -9.9 to 65.0 °C 1 °C at -10 °C or less |
Resolution (Humi.) | 0.1 % RH at 15.0 to 99.9 % RH 1 % RH at less than 15.0 % |
Accuracy (Temp.) | +/- (0.1 °C + 1 digit) |
Accuracy (Humi.) | +/- (0.1 % RH + 1 digit) |
Probes Connected | SK-LTH II series probes |
Sampling (Display) | About 1 sec. |
Communication | USB |
Operation Ambient | -10 to 60 °C, no condensing |
Storage Ambient | 0 to 50 °C |
Power Requirement | AAA size Alkaline battery x 2 |
Battery Life | More than 500 hours |
Dimensions | 100W x 73H x 22D mm |
Weight | About 123 g (exclusive of batteries) |
Material | ABC resin |
Product Scription
Temperature and Humidity Measurement Type Datalogger